We offer a wide assortment of Portable Manometers & Anemometers at industry leading price. These devices are widely appreciated for their efficiency and durability. We are one of the leading manufacturer of portable manometers & anemometers these are manufactured from quality material and are easily available at very reasonable price.

Specifications:

  • Current/voltage: 0 to 2.5v, 0 to 10v and 0 to 4-20mA
  • Climatic conditions: -20 to +80°c, 5 to 95%Rh and 800 to 1,100hPa
  • Power supply: 18 to 30VDC, 24VAC/VDC

Yes! I am Interested
View PDF
REQUEST CALLBACK
Ask Latest Price
These Temperature Probes are manufactured from quality material, with cost effective method. These are known for their competitive price, reliability and durability all over the world. Our temperature probes are highly in demand in market. These probes are ready to work in heavy work environment.

Specifications:

  • Temperature: -50 to +400 °C
  • Output: 4 to 20 mA or 0 to 10 V
  • Bracket: Stainless Steel

Yes! I am Interested
View PDF
REQUEST CALLBACK
Ask Latest Price
We offer complete range of Temperature Probes for different application areas. This range of temperature probes are highly appreciated for their accuracy and durability. Our products find their application in research and development lab, chemical, food and pharmaceutical industries. They are made of superior quality raw materials and we offer them at industry leading prices.

Specifications:

  • Temperature: -50 to +400oc
  • Length: 1000 to 2000mm
  • Output: 0 to 10 v/4-20mA

Yes! I am Interested
View PDF
REQUEST CALLBACK
Ask Latest Price
We offer a diversified range of Explosion Proof Instruments for different application areas. This range includes all electrical devices and protective systems used to minimize the effect of explosion. It includes controllers, single and binary sensors, transducer, actuators and similar devices. We manufacture these devices by high quality raw materials and sophisticated machinery. These devices are fully certified and approved from inspection companies.

Specifications:

  • Dimensions (H×W×D): 177×107×66mm
  • Power: 24 VAC/DC
  • Speed control range: 50 to 10.000min-1


Additional Information:
  • Item Code: At-Ex-Sil
Yes! I am Interested
View PDF
REQUEST CALLBACK
Ask Latest Price
We offer a wide range of Explosion Proof Instruments, these are manufactured from quality material, and are easily available at very reasonable price. Client satisfaction is our main motive, keeping this in mind we manufacture world class explosion proof instrument. These are known for their reliability, durability etc.

Specifications:

  • Power supply: 24 to 240v AC/DC
  • Dimensions: (H×W×D) 210×95×80 mm
  • Shaft connection: 12×12 mm


Additional Information:
  • Item Code: Ex-Atex
Yes! I am Interested
View PDF
REQUEST CALLBACK
Ask Latest Price
We offer unique quality Digital Portable Manometers at industry leading price. These devices are manually operated. Kimo HVAC Instruments have a full range for all HVAC applications and for all applications which require precise measurements of pressure. Some interesting features of this product are the digital display with programming key pad. Soft ware analysis can be provided as a total solution for all customers.

Specifications:

  • Overpressure allowed: MP 100:250 m bar, MP 101:700 m bar
  • Display: 2 lines, LCD technology
  • Sizes: 50x34.9 mm
  • Keypad: Metal-coated with 5 keys
  • Operating temperature: 0 to 50°c
  • Storage temperature: -20 to +80°c
  • Weight: 190 gm
  • Languages: French, English
  • Keypad: Metal-coated with 5 keys

Yes! I am Interested
View PDF
REQUEST CALLBACK
Ask Latest Price
We offer a wide assortment of Sound Level Meter for industrial applications. Digital Sound, noise and DB meters, are fully digital sound meters used for sound monitoring. One can monitor the noise or sound level generated in a factory, airport or hotel to meet the international standards of noise pollution and sound levels generated by large machines. Our sound meters allow data storage and measurements. We offer these meters at industry leading prices.

Specifications:

  • Analogue output: 0-10VDC
  • Humidity: 0 to 90%hr
  • Dimensions: 270x70x40 mm
  • Weight: 280 gm
  • Screen: Graphic display 240x160 pixels
  • Keypad: 8 sensitive keys

Yes! I am Interested
View PDF
REQUEST CALLBACK
Ask Latest Price

CO Carbon Monoxide Detector
Hand Held Portable.
Key Point

Easy to use

HOLD function

Built-in probe

Auto shut-off : 20 minutes

Feature of the Housing

71.5 mm

147.9 mm

34.2 mm

26 mm

110 mm

Material :

Protection :

 

Display :

Height of digits :

Values : 9.2 mm

Units : 4.7 mm

Weight :

Technical Feature

Parameter Temperature

Measuringunits
Measuring Range
Accuracy*
Resolution
Response time
Measuring elements
Operating temperature
Storage temperature
Power supply
Battery life
Conformity

Directives CEM 2004/108/CE and NF EN 61010-1

200 hours

4 batteries AAA LR03 1.5 V

From -20 to +80 °C

From 0 to +50 °C

NTC Electrochemical sensor

T63 = 5 s T63 = 35 s

0.1 °C 0.1 ppm

±0.4% of reading ±0.3°C From 0 to 100 ppm : ±3 ppm

From100 to 500 ppm : ±3% of reading

From -20 to +80 °C From 0 to 500 ppm°C, °F ppm

200 g (with batteries)

1 line

LCD 1 x 5 digits

Size : 50 x 20 mm

IP54

ABS


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Tachometer CT 50
Class 50.

Key Point

Easy to use

HOLD function

Built-in probe

Auto shut-off : 20 minutes

Feature of the Housing

Material :

Protection :

Display :

Height of digits :

Values : 9.2 mm

Units : 4.7 mm

Weight :

Technical Feature

Parameter Optical velocity Contact velocity

Measuring units

Measuring Range

Accuracy*

Resolution

Measuring elements

Operating temperature

Storage temperature

Power supply

Battery life

Conformity

Directives CEM 2004/108/CE and NF EN 61010-1

20 hours

4 batteries AAA LR03 1.5 V

From -20 to +80 °C

From 0 to +50 °C

Photo transistor, sighting distance

max. 40cm

ETC Adapter positioned on optical probe 1 rpm 1 rpm

From 60 to 10 000 rpm : ±0,3 % of reading ± 1 rpm

From 10 001 to 60 000 : ±30 rpm From 30 to 20 000 rpm : ±1 % of reading

±1 rpm

From 0 to 60 000 rpm From 0 to 20 000 rpm

rpm rpm, m/min, ft/min, in/min, m/s

200 g (with batteries)

1 line

LCD 1 x 5 digits

Size : 50 x 20 mm

IP54

ABS


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Thermo Hygrometer
Temperature and Humidity
Class 50 Hand Portable.

Key Point

Easy to use

Hold function

Built-in probe

Auto shut-off : 20 minutes

Feature of the Housing

Material :

Protection :

Display :

Height of digits :

Values : 9.2 mm

Units : 4.7 mm

Weight :

Technical Feature

1

34.2 mm

13 mm

48 mm

71.5 mm

147.9 mm

Parameter Temperature Hygrometry

Measuring Units

Measuring range

Accuracy: 1

Uncertainty adjustment in factory:

Drift linked to the temperature:±0.04 x (T-20) %HR (if T<15°C or T>25°C)

Resolution

Response time

Operating temperature

Storage temperature

Measuring element

Power supply

Battery life

Conformity

 

Directives CEM 2004/108/CE and NF EN 61010-1

100 hours

4 batteries AAA LR03 1.5 V

Digital sensor CMOS

From -20 to +70 °C

From -10 to +50 °C

T63 = 5 s T63 = 4 s

0.1 °C 0.1%HR

±0.88

%HR

 

±0.4% of reading ±0.3°C

Accuracy* (Repeatability, linearity,

hysteresis)


: ±1.8%HR (from 15°C to 25°C)

From -20 to +70 °C From 5 to 95%RH

°C, °F %RH

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with calibration compensation

*In accordance with NFX 15-113 and the charter 2000/2001 Hygrometers, GAL (guarantee accuracy limit) which has been calculated with a coverage factor value of 2 is ±2,68 % RH between 15 and 25°C on the measuring range from 3 % to

98 %HR. The sensor drift is less than 1 % RH/year.


200 g (with batteries)

1 line

LCD 1 x 5 digits

Size : 50 x 20 mm


IP54

ABS



Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price
Propeller Thermo-anemometer
Lv 50
Key Points
Easy To Use
Hold Function
Built-in Propeller
Auto Shut-off : 20 Minutes
Features Of The Housing
Material :
Protection :
Display :
Height Of Digits :
Values : 9. 2 Mm
Units : 4. 7 Mm
Diameter Of The Propeller :
Weight :
Technical Features
*
All The Accuracies Indicated In This Technical Datasheet Were Stated In Laboratory Conditions, And Can Be Guaranteed For Measurements Carried Out In The Same Conditions, Or Carried Out With Calibration Compensation
.
Ø 106. 1 Mm
106. 1 Mm
147. 9 Mm 145. 4 Mm
71. 5 Mm
45 Mm
34. 2 Mm
45 Mm
Parameter Temperature Velocity
Measuring Units
Measuring Range
Accuracy*
Resolution
Response Time
Measuring Elements
Operating Temperature
Storage Temperature
Power Supply
Battery Life
Conformity
Directives Cem 2004/108/ce And Nf En 61010-1
70 Hours
4 Batteries Aaa Lr03 1. 5 V
From -20 To +80 °c
From 0 To +50 °c
Ctn Hall Effect Sensor
T63 = 5 S T63 = 4 S
0. 1 °c From 0. 3 To 3 M/s : 0. 01 M/s
From 3. 1 To 35 M/s : 0. 1 M/s
±0. 4% Of Reading ±0. 3°c From 0. 3 To 3 M/s : ±3% Of Reading ±0. 1 M/s
From 3. 1 To 35 M/s : ±1% Of Reading ±0. 3 M/s
From -20 To +80 °c From 0. 3 To 35 M/s
°c, °f M/s, Fpm, Km/h
200 G (with Batteries)
100 Mm
1 Line
Lcd 1 X 5 Digits
Size : 50 X 20 Mm
Ip54
Abs
Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Lux meter

LX 50

Key Point

Easy to use

HOLD function

Built-in probe

Auto shut-off : 20 minutes

Feature of the Housing

Material :

Protection :

Display :

Height of digits :

Values : 9.2 mm

Units : 4.7 mm

Weight :

Technical Feature

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with calibration compensation.

71.5 mm

147.9 mm

34.2 mm

46 mm

45.1 mm

19 mm

22 mm

23.3 mm

Parameter Light

Measuring units

Measuring range

Accuracy

Resolution

Measuring element

Spectral range

Estimation of uncertainty on V(λ) (f1)

Directional sensitivity (f2)

Linearity

Operating temperature

Storage temperature

Power supply

Battery life

Conformity

Directives CEM 2004/108/CE and NF EN 61010-1

20 hours

4 batteries AAA LR03 1.5 V

From -10 to +70 °C

From 0 to +50 °C

<3%

<6%

<10%

In accordance with the standard photopic curve V (λ) NF C 42-710 class C

Silicon Photodiode

From 0 to 999.9 lux : 0.1 lux / from 1000 to 10000 lux : 1 lux

From 0 to 0.9999 klux : 0.0001 klux / from 1 to 10 klux : 0.001 klux

From 0 to 99.99 fc : 0.01 fc / from 100 to 929 fc : 0.1 fc±3% of reading ±3 lux

From 0 to 10000 lux / From 0 to 10 klux

From 0 to 929 fclux, klux, fc

200 g (with batteries)

1 line

LCD 1 x 5 digits

Size : 50 x 20 mm

IP54

ABS


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Manometer

MP 50 – MP 51

KEY POINTS

Easy to use

HOLD function

Auto shut-off : 20 minutes

Manual auto zero

Feature of the Housing

Material :

Protection :

Display :

Height of digits :

Values : 9.2 mm

Units : 4.7 mm

Weight :

Technical Feature

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with calibration compensation.

71.5 mm

147.9 mm

34.2 mm

22 mm

8.6 mm

6.2 mm

Parameter MP50 MP51

Measuring units

Measuring range

Accuracy*

Resolution: 2O

Response time

Operating temperature

Storage temperature

Measuring element

Power supply

Battery life

Conformity

Directives CEM 2004/108/CE and NF EN 61010-1

180 hours

4 batteries AAA LR03 1.5 V

Piezoresistive sensor

From -20 to +80 °C

From 0 to +50 °C

T63 = 0.3 s

1 Pa From -200 to +200 mmH2O : 0.1 mmH2 O

Beyond : 1 mmH

±0.5% of reading ±2 Pa ±0.5% of reading ±2 mmH2 O From -1000 to +1000 Pa From -1000 to +1000 mmH2 OPa, mmH2O, inWg, daPa mmH2

O, k Pa, in Wg, m bar, mm Hg, daPa

200 g (with batteries)

1 line

LCD 1 x 5 digits

Size : 50 x 20 mm

IP54

ABS


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Atmospheric pressure

MP 55

KEY POINTS

Easy to use

HOLD function

Built-in probe

Autozero : 20 minutes

Feature of the housing

Material :

Protection :

Display :

Height of digits :

Values : 9.2 mm

Units : 4.7 mm

Weight :

Technical Specification

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with calibration compensation.

14.1 mm

6.2 mm

71.5 mm

147.9 mm

34.2 mm

Parameter MP55

Velocity

Measuring units

Measuring range

Accuracy*

Resolution

Response time

Measuring elements

Operating temperature

Storage temperature

Power supply

Battery life

Conformity

Directives CEM 2004/108/CE and NF EN 61010-1

180 hours

4 batteries AAA LR03 1.5 V

Piezo resistive sensor

From -20 to +80 °C

From 0 to +50 °C

Barbed connectors, Ø6.2 mm made of nickelled brass

T63 < 10 s

0.1 mbar / 0.1 mm Hg / 0.1 h Pa ±2 m bar

From 700 to 1100 m bar

mbar, mm Hg, h Pa

200 g (with batteries)

1 line

LCD 1 x 5 digits

Size : 50 x 20 mm

IP54

ABS


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price
Thermometer
Tk 50 – Tk 52
Key Points
Easy To Use
Hold Function
Detachable Probe
Auto Shut-off : 20 Minutes
Features Of The Housing
Material :
Protection :
Display :
Height Of Digits :
Values : 9. 2 Mm
Units : 4. 7 Mm
Weight :
Technical Features
*
All The Accuracies Indicated In This Technical Datasheet Were Stated In Laboratory Conditions,  And Can Be Guaranteed For Measurements Carried Out In The Same Conditions,  Or Carried Out With Calibration Compensation
** The Accuracy Is Expressed Either By A Deviation In °c Or By A Percentage Of The Value Concerned: Only The Bigger Value Is Considered.
.
71. 5 Mm
147. 9 Mm
34. 2 Mm
76. 7 Mm
Tk 50
76. 7 Mm
Tk 52
Parameter Temperature
Measuring Units
Measuring Range
T : From -200 To +400 °c ; Thermocouple S
: From 0 To +1760 °c
Accuracy*
T : ±0. 5°c Or ±0. 4% Reading Value** ; Thermocouple S
: ±1°c Or ±0. 4% Reading Value**
Channels Number
Resolution
Response Time
Measuring Elements
Operating Temperature
Storage Temperature
Power Supply
Battery Life
Conformity
Directives Cem 2004/108/ce And Nf En 61010-1
180 Hours
4 Batteries Aaa Lr03 1. 5 V
From -20 To +80 °c
From 0 To +50 °c
Thermocouple K,  J,  T,  S
T63 = 5 S
0. 1 °c
Tk50 : 1 Channel
Tk52 : 2 Channels
Thermocouple K : ±1. 1°c Or ±0. 4% Reading Value** ; Thermocouple J
: ±0. 8°c Or ±0. 4% Reading Value**
Thermocouple
Thermocouple K : From -200 To +1300 °c ; Thermocouple J
: From -100 To +750 °c
Thermocouple
°c,  °f
200 G (with Batteries)
1 Line
Lcd 1 X 5 Digits
Size : 50 X 20 Mm
Ip54
Abs
Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Thermometer

TR 50 – TR 52

2 Channel Thermometer.

KEY POINTS

Easy to use

HOLD function

Detachable probe

Auto shut-off : 20 minutes

FEATURES OF THE HOUSING

Material :

Protection :

Display :

Height of digits :

Values : 9.2 mm

Units : 4.7 mm

Weight :

TECHNICAL FEATURES

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with calibration compensation

71.5 mm

147.9 mm

34.2 mm

76.7 mm

TR 50

76.7 mm

TR 52

Parameter Temperature

Measuring units

Measuring range

Accuracy*

Resolution

Channels number

Response time

Measuring element

Operating temperature

Storage temperature

Power supply

 

Battery life

Conformity

Directives CEM 2004/108/CE and NF EN 61010-1

180 hours

4 batteries AAA LR03 1.5 V

From -20 to +80 °C

From 0 to +50 °C

Pt100 Class A

T63 = 5 s

TR50 : 1 channel

TR52 : 2 channels

0.1 °C

±0.4% of reading ±0.3°C

From -100 to +400 °C

°C, °F

200 g (with batteries)

1 line

LCD 1 x 5 digits

Size : 50 x 20 mm

IP54

ABS


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Hotwire Thermo-anemometer

VT 50

KEY POINTS

Easy to use

HOLD function

Hotwire probe

Auto shut-off : 20 minutes

Feature of the Housing

Material :

Protection :

Display :

Height of digits :

Values : 9.2 mm

Units : 4.7 mm

Weight :

Technical Feature

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with calibration compensation

Parameter Temperature

Velocity

Measuring units

Measuring range

Accuracy*

Resolution

Response time

Measuring elements

Operating temperature

Storage temperature

Power supply

Battery life

Conformity

Directives CEM 2004/108/CE and NF EN 61010-1

40 hours

4 batteries AAA LR03 1.5 V

From -20 to +80 °C

From 0 to +50 °C

NTC Thermistor with a negative temperature coefficient

T90 = 1 s for Vair

= 1 m/s T63 = 6 s

0.1 °C From 0 to 3 m/s : 0.01 m/s

From 3 to 30 m/s : 0.1 m/s

±0.3% of reading ±0.25°C From 0.15 to 3 m/s : ±3% of reading ±0.05 m/s

From 3.1 to 30 m/s : ±3% of reading ±0.2 m/s

 

From -20 to +80 °C From 0.15 to 30 m/s

°C, °F m/s, fpm, km/h

200 g (with batteries)

1 line

LCD 1 x 5 digits

Size : 50 x 20 mm

IP54

ABS


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

=DF 110

Detector of refrigirant gases and

hydrogen (H2

) Gas Detector.

KEY POINTS

TECHNICAL FEATURES

HCFC :

R22

R134a, R404a, R407c, R410a, R32, R422a/b/c/d,

R425a, R507a, R125

CFC :

Others : H2

Indication

Probe

Autonomy

Housing

Keypad

Conformity

Power supply

Ambiance

Operating temperature

Storage temperature

Auto-extinction

Weight

REGLE MENTATIONS

The refrigerant gas detector complied with the EN 14624 standard that

determines the following points : - Fixed and on the go minimum

threshold of sensitivity : 1 g/year

(minimum)

- Minimum time of detection (1g/an) : 

- Detection of mixtures 5% hydrogen - 95% nitrogen (Nidron 5...)

- Heated diode sensor

- 3 modes of sensitivity (high, low and normal)

- Manual and automatic autozero

Specification

Mode Indicative measuring range (g/an)

Visual alarm

Low sensitivity ( “B” on the device)

From 0 to 300 g/an All the leds (8) for 300g/an

Normal sensitivity (“Norm” on the device)

From 0 to 30 g/an All the leds (8) for 30 g/an

High sensitivity (“H” on the device)

From 0 to 3 g/an All the leds (8) for 3 g/an

Verification

Certificate*

*According to the decree number 2007-737

1 second
- Detection of all the HCFC and HFC refrigerants

295 g

15 min

From -20 to +80 °C

From 0 to +50 °C

Neutral gas

4 AAA LR03 1.5 V batteries

EMC 2004/108/CE and EN 61010-1 Directives

3 keys

Anti-choc ABS, protection IP54

> 12 hours

Flexible, 400 mm length

LED : gradual lighting up when the gas concentration increases

Audible : the beep frequency increases when the gas concentration increases

, R290, R600a, HFO-1234yf

R12 et R502


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Gas leak detector

FG 110

Detection of gas such as methane(CH4 ), LPG ( isopropanol and isobutane) and others combustible gas (hydrocarbons).

Hold function

Alarm (from 1000 to 10000 ppm)

Display of minimum and

maximum values

Configurable auto shut-off

Backlight

 



KEY POINTS

- Hold-min-max function

- Adjustable back-light

FUNCTIONS

Detection of gas such as methane

(CH

4

), LPG ( isopropanol and

isobutane) and others combustible

gas (hydrocarbons)

Hold function

Alarm (from 1000 to 10000 ppm)

Display of minimum and

maximum values

Configurable auto shut-off

Backlight

TECHNICAL FEATURES

Measuring element

 

Display

 

Probe

 

Housing

 

Keypad

 

Conformity

 

Power supply

 

Autonomy

 

Ambience

 

Operating temperature

 

Storage temperature

 

Auto shut-off

 

Weight

 

- Easy to use

- Indication of gas leaking in ppm, %vol

or %LEL

SPECIFICATIONS

1

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out

with calibration compensation

%LEL :

 

%VOL :

 

is the limiting concentrations of gas (in air) that is needed for the gas to ignite and

explode expressed in percentage of volume in air.

is the limiting concentrations of gas (in air) that is needed for the gas to ignite and

explode.

295 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

Neutral Gas

20 houres

4 batteries AAA LR03 1.5 V

Directives CEM 2004/108/CE and NF EN 61010-1

5 keys

ABS, protection IP54

Flexible, 330 mm

4 lines, LCD technology. Sizes 50 x 36 mm

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (unit)

semiconductor sensor


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Air quality

AQ 110

KEY POINTS

- Selection of units

- Adjustable backlight

FUNCTIONS

 

 

Selection of temperature units

 

 

 

Hold function

 

 

 

Display of minimum and

maximum values

 

 

 

Configurable Auto shut-off

 

 

 

Backlight

- Easy to use

- hold-min-max Function

 

 

SPECIFICATIONS

TECHNICAL FEATURES

Measuring elements CO

2 :

Temperature :

 

Display

 

Cable

 

Housing

 

Keypad

 

Conformity

 

Power supply

 

Battery life

 

Ambience

 

Operating temperature

 

Storage temperature

 

Auto shut-off

 

Weight

 

Measuring units Measuring range Accuracy

1

Resolution

CO

 

 

2

 

ppm From 0 to 5000 ppm ±3 % of reading ±50 ppm 1 ppm

Temperature

°C, °F From - 20 to +80

°C ±0.4% of reading ±0.3°C 0.1°C

*Except class 110 S

MAINTENANCE

SUPPLIED WITH

Instruments are supplied with :

 

 

Calibration certificate*

 

 

 

Transport case

 

ACCESSORIES

CQ 15 :

 

RTE :

 

2

concentration.

 

Non dispersive infrared absorbance

Infrared light Gas sample

Wavelength Wavelength

Infrared sensor

OPERATING PRINCIPLES

DIMENSIONS

71.5 mm

147.9 mm

34.2 mm

76.7 mm

MT 51 :

 

Thermometer : CTN Probe

Negative temperature coefficient probes are thermistors with a resistance that

decreases with temperature according to the equation below:.

RT= resistance sensor value at temperature T

R(T

0)= resistance sensor value at reference temperature T

0

 

T and T

0

in °C

 

 

and T0

sensor specific constants

 

ABS Transport

case

 

Telescopic extension, length

1m, with index at ±90°

All the gases absorbs the light at a specific wavelength, a part of the light emitted by the

infra-red source is absorbed by the gas sample. The quantity of light read by the infrared

sensor is inversely proportional to the CO

 

Magnetic protective

housing

 

340 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

Neutral gas

20 hours

4 batteries AAA LR03 1.5 V

Directives EMC 2004/108/CE and EN 61010-1

5 keys

ABS, protection IP54

Retractable, length. 0.45 m, extension : 2.4 m

4 lines, LCD technology. Sizes 50 x 36 mm

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (unit)

 

NTC

infrared sensor


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

CO meter

CO 110

KEY POINTS

-

Easy to use

- Adjustable backlight

FUNCTIONS

CO maximum

2 configurable alarms

Selection of temperature units

Hold function

Display of minimum and maximum

values

Adjustable and reseatable Auto

shut-off

Backligh

t

-

CO max display

- Two configurable alarm threshold

s

SPECIFICATIONS

Measuring units Measuring range Accuracy

1

Resolution

CO

ppm

From 0 to 100 ppm

From 100 to 500 ppm

±3 ppm

±3 % of reading

0,1 ppm

Ambient temperature

°C, °F From - 20 to +80 °C ±0.4% of reading

±0.3°C

0,1°C

TECHNICALS FEATURES

Measuring elements CO :

 

Température :

 

Display

 

Cable

 

Housing

 

Keypad

 

Conformity

 

Power supply

 

Battery life

 

Ambience

 

Operating temperature

 

Storage temperature

 

Auto shut-off

 

Weight

 

1

 

*Except class 110 S

OPERATING PRINCIPLES

Electrochimical sensor

OH

-, HCO A

3

-

, CO

3

2-

Gas

Air

Working electrode

Backing electrode

Alkaline

Electrolytes

e

-

Thermometer : NTC probe

Negative temperature coefficient probes are thermistors with a resistance that decreases

with temperature according to the equation below:

RT= resistance sensor value at temperature T

R(T0)= resistance sensor value at reference

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or

carried out with calibration compensation

310 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

Neutral Gas

200 hours

4 batteries AAA LR03 1.5 V

Directives EMC 2004/108/CE and EN 61010-1

5 keys

ABS, protection IP54

Retractable, lenght. 0.45 m, extension : 2.4 m

4 lines, LCD technology. Sizes 50 x 36 mm

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (unit)

NTC

electrochemical sensor


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Tachometer

CT 110

KEY POINTS

-

Easy to use

- Adjustable backlight

- contact/optical selection

 

FUNCTIONS

 

Contact / optical selection

 

Selection of tachometer units

 

Hold function

 

Display of minimum and maximum

values

 

 

Configurable auto shut-off

 

Backlight

- hold-min-max function

- Selection of units

 

TECHNICAL FEATURES

Measuring elements Optical tachometry :

 

Contact tachometry :

 

Display

 

Cable

 

Housing

 

Keypad

 

Conformity

 

Power supply

 

Ambience

 

Température d'utilisation

 

Température de stockage

 

Auto shut-off

 

Weight

 

SPECIFICATIONS

Measuring units Measuring range Accuracy

1

Resolution

 

Optical tachometer

rpm From 0 to 60 000

rpm

From 60 to 10 000 rpm : ± 0,3 % of

reading ± 1 rpm

From 10 001 to 60 000 RPM : ±30

1 rpm

Contact tachometer

rpm, m/min,

ft/min, in/min, m/s

From 0 to 20 000

rpm

From 30 to 20 000 rpm: ± 1 % of

reading ± 1 rpm

 


1 rpm

 

*All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with

calibration compensation

*Except class 110 S

OPERATING PRINCIPLES

Contact tachometry

Disk in rotation

Probe in rotation

Frequency =

disk velocity

No reflection= No signal

Mirror in rotation

Lightbeam

Reflected

beam

Lightsensitive

cell

Reflection=si

gnal

Optical tachometry

DIMENSIONS

MAINTENANCE

SUPPLIED WITH

Instruments are supplied with :


Optical tachometry probe Ø 17 mm,

length. 195 mm

 

Tip of contact tachometry

 

A reflective tape

 

Calibration certificate*

 

Transport case (ref : ST 110)


ACCESSORIES

RTE :


GUARANTEE

MT 51 :

 

71.5 mm

147.9 mm

34.2 mm

76.7 mm

Ø40 mm

60 mm

30 mm

CQ 15 :

 

Magnetic protective

housing

 

ABS

transport case

 

Telescopic extension,

length 1m, with index at ±90°

 

190 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

Neutral Gas

4 batteries AAA LR03 1.5 V

Directives EM C 2004/108/CE and EN 61010-1

5 keys

ABS, protection IP54

Coiled, length. 0.45m, extension : 2.4 m

4 lines, LCD technology. Sizes 50 x 36 mm

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (unit)

 

ETC adaptator for optical

tachometry probe

 

optical detection

(Phototransistor sighting distance max. 40 cm)

 


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Gas leak detector

FG 110

KEY POINTS

- Hold-min-max function

- Adjustable back-light

FUNCTIONS

 

Detection of gas such as methane

(CH4

), LPG ( isopropanol anisobutane) and others combustible

 

gas (hydrocarbons)

 

 

Hold function

 

Alarm (from 1000 to 10000 ppm)

 

 

Display of minimum and

maximum values

 

 

Configurable auto shut-off

 

Backlight

 

TECHNICAL FEATURES

Measuring element

 

 

semiconductor sensor

 

Display

 

Probe

 

Housing

 

Keypad

 

Conformity

 

Power supply

 

Autonomy

 

Ambience

 

Operating temperature

 

Storage temperature

 

Auto shut-off

 

Weight

 

- Easy to use

- Indication of gas leaking in ppm, %vol

or %LEL

SPECIFICATIONS

1

 

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out

with calibration compensation

 

 

%LEL :

 

%VOL :

 

is the limiting concentrations of gas (in air) that is needed for

is the limiting concentrations of gas (in air) that is needed for the gas to ignite and

explode.

 

295 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

Neutral Gas

20 houres

4 batteries AAA LR03 1.5 V

Directives CEM 2004/108/CE and NF EN 61010-1

5 keys

ABS, protection IP54

Flexible, 330 mm

4 lines, LCD technology. Sizes 50 x 36 mm

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (unit)

 


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Thermo-hygrometer

HD 110

KEY POINTS

-

Easy to use

- Adjustable blacklight

- Hold-min-max functions

 

- Selection of unit

easuring element

 

Digital sensor (CMOS)

 

 

Display

 

Cable

 

Housing

 

Keypad

 

Conformity

 

Power supply

 

Battery life

 

Ambiance

 

Operating temperature (instrument)

 

Operating temperature (probe)

 

Storage temperature

 

Auto shut-off

 

Weight

 

Thermo-hygrometer

HD 110

KEY POINTS

-

Easy to use

- Adjustable blacklight

- Hold-min-max functions

- Selection of units

 

FUNCTIONS

 

Relative humidity, dew point and

temperature measurements

 

 

Selection of units (temperature and

dew point)

 

 

Hold Function

 

Display of minimum and maximum

values

 

 

Adjustable and reseatable auto shutoff

 

Backlight

 

SPECIFICATIONS

Measuring units Measuring range Accuracy

1

Resolution

 

Relative humidity

%HR From 5 to 95

%HR

Accuracy* (Repetability, linearity, hysteresys) :

±1,8 %HR (from 15 °C to 25 °C)

Factory calibration uncertainty :

 

Drift linked to the temperature :

 

0,1 %HR

Dew point

°C

td, °F

td

 

From -40 to +70

°C

 

td

 

±0.8% of reading ±0.6°C

td 0,1 °C

td

 

Ambient temperature

°C, °F From -20 to +70

°C ±0.4% of reading ±0.3°C 0,1 °C

*All accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions, or carried out with required compensation.

As per NFX 15-113 and the Charter 2000/2001 HYGROMETERS, GAL (Guaranteed Accuracy Limit) which has been calculated with a coverage factor value of 2 is ±2.68%RH between 15 and 25°C

on the measuring range from 5 to 95%RH. Sensor drift is less than 1%RH/year.

*Except class 110 S

 

±0,04 x (T-20)

%HR

(fi T < 15°C or T > 25°C)

 

 

±0,88 %HR

 

310 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From -20 to +70 °C

From -10 to +50 °C

Neutral gas

150 hours

4 batteries AAA LR03 1.5 V

Directives CEM 2004/108/CE and NF EN 61010-1

5 keys

ABS, protection IP54

Coiled, length 0.45 m, expanding to 2.4 m

4 lines, LCD technology. Sizes 50 x 36 mm

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (units)

 


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Vane probe thermo-anemometer

LV 110 – LV 111 – LV 117

KEY POINTS

- Airflow calculation

- Automatic average

FUNCTIONS

 

Airflow calculation

 

 

 

Airflow calculation with cone (LV 110/117)

 

 

 

Automatic average

 

 

 

Selection of units (air velocity, airflow and

temperature)

 

 

 

 

Hold function

 

 

 

Display of minimum and maximum values

 

 

 

Configurable auto shut-off

 

 

 

Backlight

 

 

 

Detection of flow direction (LV 110/117)

 

 

 

Selection of the type of cone

 

 

 

Dimensions of rectangular and circular

duct

- Hold-min-max function

- Selection of units

 

 

TECHNICAL FEATURES

Measuring elements Air velocity :

 

Ambient temperature :

 

Display

 

Vane probe diameter LV111 :

 

LV110 :

 

Cable

 

Housing

 

Keypad

 

Conformity

 

Power supply

 

Battery life

 

Ambience

 

Operating temperature (instrument)

 

Operating temperature (probe)

 

Storage temperature

 

Auto shut-off

 

Weight

 

SPECIFICATIONS

Models Measuring

units

Measuring

range

Accuracy

1

Resolution

 

Air velocity

LV111 : Ø 14 mm m/s, fpm, km/h From 0.8 to 25 m/s

From 0.8 to 3 m/s : ±3% of

reading ±0.1 m/s

From 3.1 to 25 m/s : ±1% of

reading ±0.3 m/s

0.1 m/s

LV110 : Ø 100 mm m/s, fpm, km/h From 0.3 to 35 m/s

From 0.3 to 3 m/s : ±3% of

reading ±0.1 m/s

From 3.1 to 35 m/s : ±1% of

reading ±0.3 m/s

0.01 m/s

0.1 m/s

LV117 : Ø 70 mm m/s, fpm, km/h From 0.4 0 to 35

m/s

From 0.4 to 3 m/s : ±3% of

reading ±0.1 m/s

From 3.1 to 35 m/s : ±1% of

reading ±0.3 m/s

0.1 m/s

Airflow

All models m³/h, cfm, l/s,

m³/s

From 0 to 99 999

m³/h

±3% of reading ±0.03 *

area (cm²) 1 m³/h

Temperature

All models °C, °F From -20 to +80 °C ±0.4 % of reading ±0.3 °C 0.1 °C

390 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

From 0 to +50 °C

Neutral gas

120 hours

4 batteries AAA LR03 1.5 V

Directives EMC 2004/108/CE and EN 61010-1

5 keys

ABS, protection IP54

Coiled, lg. 0.45 m, extension : 2.4 m

Ø 100 mm

Ø 14 mm / LV117 :

Ø 70 mm

4 lines, LCD technology. Sizes 50 x 36 mm

2 lines of 5 digits with 7 segments (value)

2 lines de 5 digits with 16 segments (unit)

 

NTC sensor

Hall effect sensor


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Manometer

MP 110 – MP 111

MP 115 – MP 112

KEY POINTS

- Easy to use

- Adjustable backlight

- Hold-min-max function

FUNCTIONS

 

 

Pressure measurement

 

 

 

Selection of units

 

 

 

Manual autozero

 

 

 

Hold function

 

 

 

Display of minimum and maximum

values

 

 

 

 

Configurable Auto shut-off

 

 

 

Backlight

- Selection of units

- Manual autozero

 

 

TECHNICAL FEATURES

Measuring elements

 

Tolerated overpressure

 

Connector

 

Display

 

Housing

 

Keypad

 

Conformity

 

Power supply

 

Autonomy

 

Ambience

 

Operating temperature

 

Storage temperature

 

Auto shut-off

 

Weight

 

PRESSURE SPECIFICATIONS

Models Measuring

units

Measuring

range

Accuracy

1

Resolution

 

MP 110

Pa, mmH

2

O

inWg, daPa

From -1000 to

+1000 Pa ±0.5% of reading ±2 Pa 1 Pa

MP 111

Kpa, mmH

 

 

2

O,

inWg, mbar,

mmHg, daPa

From -1000 to

+1000 mmH

 

 

2

O

±0.5% of reading ±2

mmH

 

 

2

O

De 0 à ±200 mmH

 

 

2

O

: 0,1 mmH

 

 

2

O

Au delà : 1 mmH

 

 

2

O

MP 115 kPa, inWg, mbar,

mmHg, PSI

From -500 to

+500 mbar

±0.5% of reading ±0.5

mbar 0.1 mbar

MP 112 kPa, inWg, mbar,

mmHg, PSI, bar

From -2000 to

+2000 mbar ±0.5% of reading ±2 mbar 1 mbar

 

 

1

 

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out

 

220 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

Neutral gas

180 hours

4 batteries AAA LR03 1.5 V

Directives EMC 2004/108/CE and EN 61010-1

5 keys

ABS, protection IP54

4 lines, LCD technology. Sizes 50 x 36 mm.

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (unit)

 

MP 110 / 111 : Ø 6.2 mm barbed connectors made of nickelled brass

MP 115 / 112 : Ø 4.6 mm threaded connectors of nickelled brass

 

MP 110 : 250 mbar / MP 111 : 700 mbar

MP 115 : 1.4 bar / MP 112 : 3 bar

 

Piezoresistive sensor


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Thermocouple thermometers

TK 110 – TK 112

KEY POINTS

-

 

Adjustable alarms

- Adjustable backlight

 

 

FUNCTIONS

 

 

Selection of temperature units

 

 

 

Adjustable alarms

 

 

 

Hold function

 

 

 

Display of minimum and maximum

values

 

 

 

 

Configurable auto shut-off

 

 

Backlight

 

 

 

Delta temperature (TK112)

 

-

 

Hold-min-max functions

- Selection of units

 

 

TECHNICAL FEATURES

Measuring elements

 

Channels number

 

Display

 

Boîtier

 

Clavier

 

Connector engineering

 

Conformité

 

Power supply

 

Battery life

 

Ambience

 

Operating temperature

 

Storage temperature

 

Auto shut-off

 

Weight

 

SPECIFICATIONS

1

 

All accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurements carried out with required

compensation.

* The accuracy is expressed either by a deviation in °C, or by a percentage of the value concerned. Only the bigger value is considered.

 

 

Models Measuring units Measuring range Accuracy

1

Resolution

 

Thermocouple probes (

see related data sheet)

 

Thermocouple

K °C, °F From -200 to +1300 °C ±1.1 °C or ±0.4%

of reading value* 0.1 °C

Thermocouple

J °C, °F From -100 to +750 °C ±0.8 °C or ±0.4%

of reading value* 0.1 °C

Thermocouple

T °C, °F From -200 to +400 °C ±0.5 °C or ±0.4%

of reading value* 0.1 °C

Thermocouple

S °C, °F From 0 to 1760 °C ±1 °C or ±0.4%

of reading value* 0.1 °C

210 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

Neutral Gas

180 hours

4 batteries AAA LR03 1.5 V

Directives EMC 2004/108/CE and EN 61010-1

Compensated miniature female connectors

5 keys

ABS, protection IP54

4 lines, LCD technology. Sizes 50 x 36 mm.

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (unit)

 

TK110 : 1 channel

TK112 : 2 channels

 

Thermocouple K, J, T ou S


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Pt100 Thermometer

TR 110 – TR 112

KEY POINTS

- Adjustable alarms

- Adjustable backlight

FUNCTIONS

 

 

Selection of temperature units

 

 

 

Adjustable alarms

 

 

 

Hold function

 

 

 

Display of minimum and maximum

values

 

 

 

 

Configurable auto shut-off

 

 

 

Backlight

 

 

 

Delta temperature (TR112)

- Hold-min-max function

- Selection of units

 

 

TECHNICAL FEATURES

Measuring element

 

Number of channels

 

Display

 

Housing

 

Keypad

 

Connector

 

Conformity

 

Power supply

 

Battery life

 

Ambience

 

Operating temperature

 

Storage temperature

 

Auto shut-off

 

Weight

 

SPECIFICATIONS

Measuring units Measuring range Accuracy

1

Resolution

 

Pt100 probes (see related data sheet)

°C, °F From -100 to +400 °C ±0.4% of reading ±0.3°C 0.1 °C

210 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

Neutral gas

180 hours

4 batteries AAA LR03 1.5 V

Directives EMC 2004/108/CE and EN 61010-1

Compensated miniature female connectors

5 keys

ABS, protection IP54

4 lines, LCD technology. Sizes 50 x 36 mm.

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (unit)

 

TR110 : 1 channel

TR112 : 2 channels

 

Pt100 class A


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Hotwire thermo-anemometer

VT 110 – VT 115

KEY POINTS

- Easy to use

- Adjustable backlight

- Automatic average

FUNCTIONS

 

Airflow calculation

 

Airflow calculation with cone

 

Selection of units (air velocity, airflow

and temperature)

 

Hold function

 

Display of minimum and maximum

values

 

Adjustable auto shut-off

 

Backlight

 

Airflow detection

 

Selection of cone

 

Dimensions of rectangular and

circular duct

 

Automatic average

 

Air velocity compensation in

atmospheric pressure

- Hold-min-max functions

- Selection of units

- Debit calculation

 

TECHNICALS FEATURES

Measuring element Hotwire air velocity :

 

Ambient temperature :

 

Display

 

Probes VT 110 :

 

VT 115 :

 

Cable

 

Housing

 

Keypad

 

Conformity

 

Power supply

 

Battery life

 

Ambience

 

Operating temperature (instrument)

 

Operating temperature (probe)

 

Storage temperature


Auto shut-off

 

Weight

 

SPECIFICATIONS

1

 

Etablies dans des conditions de laboratoire, les exactitudes présentées dans ce document seront maintenues sous réserve d'appliquer les compensations nécessaires ou de se ramener à

des conditions identiques.

 

Measuring

units

Measuring range Accuracy

1

Resolution

 

Velocity (hotwire)

m/s, fpm, km/h From 0.15 to 30 m/s

From 0.15 to 3 m/s : ± 3% of

reading ± 0.05 m/s

From 3.1 to 30 m/s : ± 3% of

reading ± 0.2 m/s

0.01 m/s

0.1 m/s

Airflow

m³/h, cfm, l/s,

m³/s

From 0 to 99 999

m³/h

±3% of reading ±0.03 x area

(cm²)

 

 

1 m³/h

 

Temperature

°C, °F From -20 to +80 °C

± 0.3% of reading ± 0.25 °C

0.1 °C

 

1

 

Etablies dans des conditions de laboratoire, les exactitudes présentées dans ce document seront maintenues sous réserve d'appliquer les compensations nécessaires ou de

se ramener à des conditions identiques.

 

 

250 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

From 0 to +50 °C

Neutral gas

180 hours

4 batteries AAA LR03 1.5 V

Directives EMC 2004/108/CE and EN 61010-1

5 keys

ABS, protection IP54

Straight, lenght : 2 m

Telescopic hotwire probe bent at 90°

Stainless hotwire probe

4 lines, LCD technology. Sizes 50 x 36 mm.

2 lines of 5 digits with 7 segments (value)

2 lines de 5 digits with 16 segments (unit)

 

NTC sensor

Thermistance with a negative

Temperature coefficient.

 


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Infrared thermometer

Kiray 300 is a thermometer used to

diagnose, inspect and check any temperature. Thanks to its

elaborated optical system with a dual laser sighting, it allows easy

and accurate measurements of little distant targets. The

KIRAY300 instrument has an internal memory which can save up to 100

measurements. Compatible with thermocouple K probe.

Spectral response.......................8 - 14 μm

Optical..........................................D.S : 50:1 (50.8 mm at 2540 mm)

Temperature range......................From -50 to +1850°C

Accuracy*....................................From -50 to +20°C : ±3°C From +20 to +500°C : ±1% ±1°C From +500 to +1000 °C : ±1.5% From +1000 to +1850°C : ±2% Infrared repeatability...................From -50 to +20°C : ±1.5°C From +20 to +1000°C : ±0.5% or ±0.5°C From +1000 to +1850°C : ±1%

Display resolution.......................0.1°C

Response time.............................150 ms Emissivity....................................Adjustable from 0.10 to 1.0 (pre-set at 0.95) Over range indication ................Display indication : « ---- »Dual laser sighting......................Wavelength : from 630 nm to 670 nm Output < 1mW, Class 2 (II) Positive or negative temperature indication................Automatic (no indication for a positive

temperature) (-) sign for a negative temperature Display.........................................3 lines, 4 digits with backlighted display

LCD
Auto-extinction ...........................Automatic after 7 seconds of inactivity High/low alarm.............................Flashing signal on display and beep signal with adjustable thresholds Power supply...............................Alkaline 9V battery Autonomy....................................95 h (inactive laser and backlight)15 h (active laser and backlight) Use temperature..........................From 0 to +10°C for a short period

From +11 to +50 °C for a long periodStorage temperature

...................From -10°C to +60°C Relative humidity........................From 10 to 90%RH in operating mode and lower than 80%RH in storage Dimensions..................................200 x 140 x 50 mm Weight..........................................320 g (included battery) Memory........................................100 temperature values Please make sure that the target is larger than the size of the laser sighting.

Technical features Distance from the target

KIRAY 300 Infrared thermometer


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

The human body is comfortable only in an environment where the

temperature and the air movements are kept within established limits.

For the comfort and good health of human or animals, the black ball

thermometer gives a direct measurement of the average radiant

temperature.

This temperature, perceived by the body, is radiated by all surrounding

surfaces, walls, floor, furniture and equipment.

The black ball thermometer is particularly useful in working area’s

veterinary laboratories and animal breeding.

 

Developed and manufactured

by KIMO, the Black Ball

Thermometer is for measuring

radiant temperature.

Based on the black body

principle, it consists of one

sphere, which is equipped with

a liquid expansion

thermometer, Pt 100 or

thermocouple temperature

probe .

It’s an accurate, reliable and

user-friendly instrument.

It's also adaptable on every

 

types of thermometers.

Sphere

Hollow in brass, ø70 mm or ø150 mm

Thickness 6/10 mm

Coating

Multi-coat paint,

High temperature 600 °C,

Mat black with 0.95 average emission coefficient

Standards

Complies with the recommandations of the NF ISO

7726 Std relative to then ''thermal environment'',

X35-201 and X35-202 Std relative to the ''thermal

constraints of the working man''

 


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

DB 200

Sound level meter

Integrating-averaging with storage function

Five Different Measurement MODES

- Mode 1 :

Conventional sound level meter

- Mode 2 :

Conventional sound level meter with storage.

- Mode 3 :

Conventional and integrating-averaging sound level meter

- Mode 4 :

Integrating-averaging sound level meter with storage.

- Mode 5 :

Sound level meter “calculator” of two sound sources.

Measured Valve

Result & Additional Information

- Maximum and minimum values, peak values

- L01-L10-L50-L90 s

tatistics distribution of measured values.

- Presence and percentage of overload input stages, measurement time.

- Residual autonomy of batteries or battery, measuring capacity remaining.

Data Display

The DB200 sound level meter is supplied with

LDB200 software for display data and measurement report printing.

- Weighted sound level :L

- Equivalent continuous level :

Leq

- Sound exposure level : LE- Peak pressure level :

Lpk

I/O Interface

Launching and stopping of the measurement by external control.

Detection of sensitive levels for alarms activation

Analogue output 0-10V DC.

Standard

As per following standards :

Sound level meter : NF EN 61672-1

(2003)- NF EN 60651 (1994) – NF EN 60804 (2000).

CE conformity: EN 61010 – EN 61000

generic and as per product standards.


Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Solarimeter

SL 100

Solar irrigation measuring rang

from 1 W/m2 to 1300 W/m 2

Energetic exposure measuring rangeFrequency of measurement

Accuracy

Calculation frequency (W/m2) Capacity of measurement (Wh/m2)

Operating temperature

Storage temperature

Housing dimensions

Autonomy

Power supply

Electronic

Electronic board

Conformity

Measurement and spot check of solar power in W/m2

- instantaneous,

- average,

- min./max. values,

- hold function

Calculation of energetic exposure in Wh/m

2 during timed dataset

Results (Wh/m2) saved when instrument is switched off

Solarimeter

SL 100

Portable autonomous solarimeter can measure solar irrigation for the control

of photovoltaic and thermal installations on test or on site:

Measurement and spot check of solar power in W/m2

- instantaneous,

- average,

- min./max. values,

- hold function

Calculation of energetic exposure in Wh/m2

during timed dataset

Results (Wh/m2) saved when instrument is switched off

Solarimeter

SL 100

Technical features

Easy to use, for immediate information

Evaluation of generated electric power,

optimum orientation of solar panels, and

performances follow-up.

Choice and determination of

thermal or photovoltaic generators features.

SL 100

Spectral response

Nominal sensitivity

Response in cosine


Yes! I am Interested
 
X

Download Brochure
Emco Group India

Chirayush Gandhi (Director)
Unit No. 5/6, Magnum Opus Plaza, Ground Floor, Vakola, Shanti Nagar, Santacruz East
Mumbai - 400055
Maharashtra, India
Send Email
© Emco Group India. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited